“Telelin” make Specialises in manufacturing of Pitot Tubes of all types for measuring Air/Gas pr LIQUID Velocities in Ducts & Pipe Lines. Pitot Tubes are manufactured as per ps/ Standards or as per given design or drawing having length and material of construction. Four different models are available to suit to customers specific application.
S- Shaped : Recommended specifically for flow / velocity measurement of dirty, particulate laden air or gas streams. Typical in environmental testing, large I.D. (1/4" or more) tubing resists chocking under harsh, sooty conditions. Again tube can be cleaned easily by passing air or water through it. Total & static pressure tubes are precisely aligned & arc welded together at every six inch, for maximum accuracy, strength and durability. 1/4" BSP (F) connections easily adapt to any type of pipe or tubing. Permanent engraved insertion depth graduation (optional) facilitates accurate positioning.
Features :
• Long lasting S.S. construction
• 1/4" BSP (F) pressure connections,
• Permanently welded • Rated for upto 815°C (1500°F) Temp.
• Required adaptors, tubing or piping can be provided.
|
Model No. |
Insertion Length |
Model No. |
Insertion Length |
PT-131-8 |
200 mm |
PT-131-60 |
1500 mm |
PT-131-12 |
300 mm |
PT-131-80 |
2000 mm |
PT-131-20 |
500 mm |
PT-131-100 |
2500 mm |
PT-131-30 |
750 mm |
PT-131-120 |
3000 mm |
PT-131-40 |
1000 mm |
PT-131-140 |
3500 mm |
Standard :
• MOC-304 S.S.
• Pipe -O.D. 3/8", I.D. 1/4"
• Pressure Connections 1/4" BSP (Female)
• Process connection nil
• Other required length, M.O.C., O.D. & I.D. Pipe, pressure connections can be provided
Optional :
• Engraved insertion depth marking
• Nozzel or other process connection adaptors
• Isolating valves
• Connecting Hose or Tubing
• D.P. Indicating Instrument
• Any other size, material of construction or tube as per your given drawing can be made & supplied.
CALIBRATION : For exact calibration i.e. constant factor, tubes can be got calibrated at I.I.T., Powai on your behalf at Aerospace Engineering Dept. in their low speed wind tunnel, Cost Rs. 18500/- + service Tax. Time required 4 to 6 weeks. I.I.T. requires full payment in advance and upto 3 nos. tubes can be calibrated in above estimate. For more than 3 Tubes, rates will change
OTHER ITEMS SUPPLIED FOR USE WITH PITOT TUBE : Inclined Tube/ U-Tube Manometer, Digital Manometer, Adaptors, Tubing, Manometric Liquid etc. can be supplied. |